Pre-1980 Pittsburgh home with 12.4 pCi/L initial radon. Mitigation outcome

Squirrel Hill home, pre-1980 construction, initial 48-hour continuous radon monitor result of 12.4 pCi/L. Three times the EPA action threshold. Documents the mitigation system design, install, and post-mitigation clearance test result.

Initial12.4 pCi/L
Post-mitigation1.9 pCi/L
EPA action4.0 pCi/L
ZoneEPA Zone 1

§

Context

A buyer under contract to purchase a 1968-construction Squirrel Hill home with a partially-finished basement retained us for pre-closing radon testing. Allegheny County is EPA Radon Zone 1. Average indoor radon levels are higher than the national average, and pre-1980 construction typically lacks sub-slab depressurization or vapor barriers. The seller had provided a free Allegheny County Health Department charcoal-canister kit result of 4.8 pCi/L; the FHA lender required a continuous radon monitor (CRM) report for the closing file.

§

Methodology

EPA short-term protocol: closed-house conditions established 12 hours prior to monitor placement; continuous radon monitor (Sun Nuclear 1028) deployed in the basement living area at 36 inches off the floor and 8 feet from interior walls; 48-hour measurement period with hourly readings recorded. Instrument was calibrated by the manufacturer within the prior 90 days per PA DEP requirements.

§

Initial reading

Final 48-hour average: 12.4 pCi/L. Hourly readings ranged from 8.2 to 18.6 pCi/L, with elevated readings during overnight hours consistent with reduced ventilation. This significantly exceeded the EPA action threshold of 4.0 pCi/L and required mitigation before closing under the FHA lender's environmental requirements.

§

Mitigation design referral

Because we do not perform radon mitigation, we referred the buyer to two independent PA-DEP-certified mitigators for competitive bids. The selected contractor installed an active sub-slab depressurization (ASD) system: PVC pipe through the basement slab to outside-discharge above roof line, in-line radon fan (Radon-Away RP-265) sized for the home's footprint, manometer pressure gauge for visual monitoring. Install cost: $1,485.

§

Post-mitigation verification

We returned 4 weeks post-install for follow-up CRM testing under closed-house conditions. Final 48-hour average: 1.9 pCi/L. Below the EPA action threshold and below the 2.0 pCi/L EPA-recommended consideration threshold. The FHA lender accepted the post-mitigation report and the closing proceeded.

Outcome

Closing proceeded with $1,485 mitigation expense (allocated 50/50 buyer/seller per the contract amendment) + $185 post-mitigation re-test. Total environmental-testing-related closing delay: 18 business days from initial test to FHA approval of post-mitigation report.

— — Takeaway

Allegheny County radon levels can be significantly higher than the typical free-kit result suggests. Kits are passive carbon canisters subject to operator handling variance + multi-day-averaging variance. A 48-hour CRM with hourly readings reveals the actual exposure profile. Buyers should not skip CRM testing on Allegheny County pre-1980 properties even when the seller-supplied kit reads at or near 4.0 pCi/L.

Related

More case studies

Same protocol applied across different scenarios. Browse the full archive or explore the real estate transactions hub.

Want more Environmental Air Solutions in your Google results?

Pick Environmental Air Solutions as a preferred source and our case studies are more likely to appear in your Top Stories, and our links can carry a Preferred badge in AI Overviews and AI Mode.

Add as preferred source

Schedule · 48hr appointment

Unsure about your air? Schedule a test.

48-hour appointment window. 24-hour lab turnaround. Licensed inspectors, unmarked vehicles, statewide coverage in NY and PA.